Function
Visual field.
ZETA threshold, GHT and sector analysis, test comparison. DPA analysis follows defect progression from one test to the next and, according to Optopol, separates short-term fluctuation from real defects.

Optopol · static and kinetic perimeter
Static or kinetic. The whole visual field.

Field
180°horizontal
Closed 300 mm aspheric bowl.
Static and kinetic
Static strategies (screening, threshold) or kinetic strategies (manual, automatic or mixed), as you choose.

Stimulus
I to Vsizes, in four colours
White, green, blue, red; white and yellow backgrounds.
Through the patient's eyes
Two families of strategies, to choose from. In static testing, points light up one by one. In kinetic testing, a stimulus glides from the edge towards the centre: where it is seen, the isopter takes shape.
Field
A closed, ventilated 300 mm aspheric bowl.
180°horizontal field
Kinetic
Alongside static strategies (screening, threshold), the PTS 2000 offers kinetic strategies; you choose one or the other according to the exam.

Our three perimeters, side by side.

PTS 2000


n/a: not stated in our sources. Sources: Optopol documentation, Topcon 2026 catalogue.
Glaucoma
To follow glaucoma, the perimeter measures function and OCT measures structure. The Optopol REVO OCT software brings the two together.
Function
ZETA threshold, GHT and sector analysis, test comparison. DPA analysis follows defect progression from one test to the next and, according to Optopol, separates short-term fluctuation from real defects.

Structure
The SOCT REVO maps retinal nerve fibre layer thickness.

Software
Perimeter results go into the OCT software: visual field defects are shown on the nerve fibre thickness map, in a one-page report.
Source: Optopol documentation. Structure-function analysis with the Optopol OCT software (perimeter software version 3.4 or later).
Source: Optopol documentation. Manufacturer specifications, subject to change.
The PTS 2000 covers fast screening, threshold and kinetic perimetry, with size I to V stimuli in four colours. Fixation monitoring tracks the gaze and detects blinks. Results go out as DICOM or GDT.
Emetrop Afrique delivers, installs and commissions the device, trains the users and maintains it in the countries we cover.
Yes: it offers static strategies and kinetic strategies (manual, automatic or mixed); you choose according to the exam.
With gaze tracking, blink detection, the Heijl-Krakau method and the EyeSee camera.
Images: Optopol
We bring it and show it to your team. No commitment.