Skip to content

Optopol · Topcon

Visual field.

Three perimeters, from fast screening to kinetic testing.

Henson 9000 · PTS 2000 · PTS 925 · approximate scale

Static perimetry

The threshold, point by point.

The patient looks at the centre of the bowl. Points of light appear one by one; the patient signals those they see.

Schematic illustration of a 24-2 grid (54 points).

All three, side by side.

  • Optopol

    PTS 2000

    The complete perimeter, static and kinetic.

    180°
    horizontal field
    I to V
    stimulus sizes, 4 colours
    17 kg
    604 × 483 × 427 mm
  • Optopol

    PTS 925

    The compact static perimeter.

    100°
    horizontal field (170° with fixation shift)
    III
    white stimulus
    9 kg
    418 × 556 × 408 mm
  • Topcon

    Henson 9000

    Fast screening and progression analysis.

    3.5 min
    for the Smart Supra test
    24-2 + 10-2
    combined in one test
    ZATA
    threshold from previous exams

Also in the range: Oculus Easyfield

All diagnostics

Compare the three perimeters.

“n/a”: not stated in our sources. In brackets: with fixation shift.

PTS 2000PTS 925Henson 9000
ManufacturerOptopolOptopolVISIA imaging (Topcon group)
Bowl300 mm, aspheric, closed300 mm, spherical, closedn/a
Horizontal field180°100° (170°)n/a
Vertical field60° (70°) up, 70° down40° (55°) up and downn/a
PerimetryStatic and kineticStaticn/a
StimulusI to V; white, green, blue, redIII, whiten/a
BackgroundWhite 3.18 and 10 cd/m²; yellow 100 cd/m²White 10 cd/m²n/a
StrategiesScreening, threshold, ZETA, TOP, Esterman, BSV, Flicker, kineticScreening, threshold, ZETA, TOP, Esterman, BSV, FlickerSmart Supra (3.5 min, 24-2 and 10-2); ZATA threshold
Follow-upn/an/aProgression analysis
FixationGaze tracking, blinks, Heijl-Krakau, EyeSeeGaze tracking, blinks, Heijl-Krakau, EyeSeen/a
ConnectivityDICOM, GDT, networkDICOM, GDT, networkn/a
Dimensions, weight604 × 483 × 427 mm, 17 kg418 × 556 × 408 mm, 9 kgn/a
Regulatoryn/an/aMDR class I

Sources: Optopol documentation, Topcon 2026 catalogue, Topcon website, declaration of conformity.

Function and structure, for glaucoma.

Visual field and OCT complement each other to monitor glaucoma: function and structure.

PTS 2000 · Maestro3

In detail.

Three automated perimeters, from fast screening to kinetic perimetry.

Choosing a perimeter

The PTS 2000 covers all perimetry, static and kinetic; the PTS 925 keeps its static strategies in a compact device; the Henson 9000 focuses on a 3.5-minute screening test and progression follow-up.

Frequently asked questions.

How does the PTS 2000 differ from the PTS 925?

The PTS 2000 adds kinetic perimetry, size I to V stimuli in four colours and a 180° horizontal field; the PTS 925 is a compact 9 kg static perimeter.

Tell us about your project.

New equipment, a replacement, a demonstration: we come to you.