Skip to content

Maestro3

Topcon · OCT, OCTA and 50° fundus camera

Topcon Maestro3 : Maestro3

One touch. One capture. The whole posterior pole.

Topcon Maestro3 – OCT, OCTA and 50° fundus camera

Highlights.

ONEscan

130,000 A-scans per second.

Macula and optic disc, 12 × 9 mm, in one acquisition.

Illustration. B-scan on the face of the volume: Topcon image.

ONEscan

One capture, four images.

In a single acquisition: the colour photograph, OCT angiography, the thickness map and the cross-section.

  • Colour fundus photograph
  • OCT angiography (option)
  • Thickness map
  • OCT cross-section

Images: Topcon Healthcare, IMAGEnet® software.

OCT

130,000 A-scans per second.

3D OCT of the macula and optic disc over 12 × 9 mm, with an 840 nm source.

130,000A-scans per second

6 µm
axial resolution, or less
20 µm
lateral resolution, or less
12 × 12 mm
OCT angiography, at its widest
3 to 12 mm
scan range

Fundus

50° in colour, from a 2.0 mm pupil.

Non-mydriatic slit-scan photography, and a mosaic over 9 fixation points.

50°field of view, ± 5%

2.0 mm
minimum pupil for photography
9
fixation points for the mosaic, about 90°
−33 to +40 D
refractive compensation, with lenses

Designed for speed.

Tap a feature to see it on the device.

  • One touch. The device aligns, focuses, captures and moves from one eye to the other automatically.

  • Rotating screen. The control panel rotates through 360°.

  • 2.0 mm pupil. Slit-scan illumination lets the fundus photograph pass through 2.0 mm pupils.

  • Anterior segment. Optional, with the AA-2 kit: 3 to 16 mm scans.

Topcon Maestro3

Have a Maestro2?

Compare it with the Maestro3, or with our other OCTs.

Maestro3

OCT speed
130,000 A-scans/s
Technology
Spectral-domain OCT, 840 nm
Fundus photography
Colour, 50°, pupils from 2.0 mm
Autofluorescence (FAF)
On the Maestro3 Plus
OCT speed
50,000 A-scans/s
Technology
Spectral-domain OCT
Fundus photography
Colour
Autofluorescence (FAF)
n/a

Learn more : Maestro2

n/a: not stated in our sources. Sources: Topcon brochures and 2026 catalogue.

Maestro3 or Maestro3 Plus.

Maestro3

  • OCT and OCT angiography (option)
  • Colour, red-free and infrared photography
  • Anterior segment (option)
  • 23.5 kg

Maestro3 Plus

  • Everything in the Maestro3
  • Fundus autofluorescence (FAF) with a dedicated filter
  • 23.9 kg

For glaucoma, with visual field testing.

Two glaucoma exams, installed together.

Maestro3 · PTS 2000

Specifications.

OCT
Speed
130,000 A-scans/s
Light source
SLD 840 nm
Resolution
Axial: 6 µm or less · lateral: 20 µm or less
Scan range
3 to 12 mm (horizontal and vertical); OCTA up to 12 × 12 mm
Scan patterns
3D, line, cross, radial, ONEscan (12 × 9 mm, macula and disc), combined
Minimum pupil
2.5 mm
Fundus
Imaging
Maestro3Colour, red-free (digital), infraredMaestro3 PlusColour, red-free (digital), infrared, autofluorescence (FAF)
Field of view
50° ± 5%
Minimum pupil
2.0 mm (small pupil); 2.5 mm (normal)
Mosaic
9 internal fixation points, about 90°
Anterior segment
Scan range
3 to 16 mm with the AA-2 kit (option); 3 to 6 mm without the kit
Patient
Refractive compensation
−13 to +12 D without lens; −33 to +40 D with lenses
Options
Software and accessories
OCT angiography, Smart Denoise, anterior segment
Power and dimensions
Power supply
100–240 V, 50–60 Hz, 110–130 VA
Dimensions
332–427 × 541–708 × 564–754 mm
Weight
Maestro323.5 kgMaestro3 Plus23.9 kg
Regulatory
Class
Medical device, MDR class IIa

Source: Topcon Maestro3 brochure (EM000090E-1, 09.26). Manufacturer specifications, subject to change.

In detail.

The whole posterior pole exam in one scan

With ONEscan, the Maestro3 captures in a single acquisition a 12 x 9 mm 3D OCT covering macula and optic disc, a colour fundus photograph and, optionally, OCT angiography. The device aligns, focuses, captures and moves from one eye to the other automatically, at the touch of a button, so technicians can perform the exam.

Who is it for?

  • Practices that want one fast device for OCT and fundus photography;
  • departments following many glaucoma and diabetic patients;
  • clinicians who want OCT angiography or autofluorescence (Maestro3 Plus) without an extra device.

Technical highlights

According to Topcon’s product page:

  • OCT and OCT angiography at 130,000 A-scans per second (OCTA and Smart Denoise optional);
  • true-colour non-mydriatic fundus imaging, 50° field, slit scanning, pupils from 2.0 mm;
  • RNFL or GCL+ / GCL++ thickness maps and retinal and optic disc vascular analysis;
  • autofluorescence on the Maestro3 Plus; anterior segment OCT optional.

Installation, training and service

Emetrop Afrique delivers, installs and commissions the device, trains users and maintains it in all the countries we cover.

Frequently asked questions.

What is the difference between Maestro3 and Maestro3 Plus?

According to Topcon, the Maestro3 Plus adds fundus autofluorescence (FAF) with a dedicated filter. All other imaging is shared by both models.

Does the Maestro3 replace the Maestro2?

Both devices are available. The Maestro3 is the faster one, at 130,000 A-scans/s; the Maestro2 remains a proven option for routine screening and follow-up. We will advise you based on your practice.

Is pupil dilation needed?

No. Fundus photography is non-mydriatic; Topcon states capture is possible through pupils as small as 2.0 mm.

Images: Topcon Healthcare

See the Maestro3 at your site?

We bring it and show it to your team. No commitment.